The Requirements for Dental Offices of Amalgamator

Elemental mercury is the primary component of dental amalgam. Mercury is a naturally occurring metal in the environment and can exist in liquid, gas or solid form when combined with other metals. Everyone is exposed to mercury through air, drinking water, soil and food. The concern is how much mercury exposure is too much before becoming mercury poisoning, and are mercury levels increasing as a result of interactions with other elements in the environment?

Mercury is released into the environment whenever a dentist removes an old amalgam filling from a cavity, or when excess amalgam is removed during the placement of a new filling. There is a concern that low levels of vapor can be inhaled and absorbed by the lungs even years after an amalgam filling is placed in a patient’s mouth, potentially causing long-term damage to the brain and kidneys. Due to the lack of scientific data surrounding this concern, little has been done over the years to limit the use and/or disposal of dental amalgamator.

In 2009, the FDA issued a final rule that classified dental amalgam as a Class II device accompanied by a document that designates special controls for dental amalgam. The Agency for Toxic Substances and Disease Registry (ATSDR) and the EPA have established mercury exposure levels aimed at protecting the most mercury-sensitive populations from the adverse effects of mercury vapor, namely pregnant women, developing fetuses and all children under 6 years old.

Dental offices that place or remove amalgam fillings are required to install and properly maintain an amalgam separator. Depending on the brand, a separator can be purchased from virtually any supply vendor or purchased directly from the manufacturer. Whatever separator is purchased; it is important that the system is promptly installed in order to comply with the new regulations. Proper documentation management is an integral part of this program to ensure that a certificate of recycling is kept on file, and a replacement canister is purchased once the marked fill line is reached or 12 months from the date of installation, whichever occurs first.

The regulations do not specify a minimum amount of time needed before replacing a used filter/canister, but the regulations do state and mandate that the manufacturer guidelines for replacement be followed. Since each amalgam separator is required to conduct testing for the ISO certification based on a 12-month replacement maximum, most amalgam separators are required to be replaced every 12 months or once the canister is full. This not only ensures that the separator is functioning as certified, but also to prevent the separator from moving into bypass mode, which would allow the wastewater to flow unrestricted or filtered directly into the separator.

The EPA recommends that an amalgam separator should be monitored monthly to ensure the canister is replaced per the manufacturer’s instructions for use, and that a backup canister is kept on site to ensure proper replacement is conducted at the appropriate time.